Intercable - Your Reliable Supplier of Network Cable, Coaxial Cable & Fiber Optic Cable...
   
 
 
Hot Product
 
RJ45-RJ45 Patch Cord

RJ45-RJ45 Patch Cord complying with Component Compliancy of TIA/EIA 568, ISO/IEC 11801. (UTP/FTP/STP/SFTP Cat.5e/Cat.6 RJ45-RJ45 Patch Cord)

More...
 
Fiber Optic Patch Cord Series
Fiber Optic Patch Cord Series. (ST/SC/FC/SMA/MU/FDDI/
ESCON/MTRJ/LC/D4/E2000
Connector Type)
More...
   
 
Instrumentation Cable
Instrumentation Cable BS5308
BS5308 Part1 Instrumentation Cable PVC Insulated
VDE Ref Code  

PVC Sheath Version

RE-Y(St)Y (Overall Screen)

RE-Y(St)Y PiMF(Individual Screen+Overall Screen)

RE-Y(St)Y-SWA(Overall Screen+Steel Wire Armour)

RE-Y(St)Y PiMF-SWA(Individual Screen+Overall Screen+Steel Wire Armour)

Construction

Conductor:Annealed solid copper(Class 1),stranded(Class2),

or fiexible(Class 5) to BS5360 .

Core/Pair identification: .

Multicore cables:

Up to 40 cores-yellow

.cores with black numbers

41-80 cores-black

cores with black numbers

Multipair cables:Colour coded

in accordance with Colour

Code Chart 2 on page 6

Pair screens

Aluminium/p.e.t.p.Laminated tape applied with the metallic

side down in electrical contact with a 0.5 mm 2 tinned copper drain wire.

A 23 micron isolation tape is applied over the screening tape with a

minimum 50% overlap.

Voltage rating

300 volt core to earth and 500 volt core to core at maximum

temperature of 65 ℃

LSOH Sheath Version:

RE-H (St)H(Overall Screen)

RE-H(St)HPiMF(Individual Screen+Overall Screen)

RE-H(St)-H-SWA(Overall Screen+Steel Wire Armour)

RE-H(St)HPiMF-SWA(Individual Screen+Overall Screen+ Steel Wire Armour

Binder tape:A 23 micron p.e.t.p.tape applied with the metallic side down in electrica contact with a 0.5 0.5mm 2 tinned copper drain wire over the p.e.t.p.binder tape.

Collective screen:

Aluminium/p.e.t.p.laminated tape applied with the metallic side

down in electrical contact with a 0.5mm 2 tinned copper

drain wire over the p.e.t.p.binder tape.

Outer protection:

Type 1 Extruded flame retardant PVC sheath.

Type 2 Extruded PVC Type TM1 ,galvanised steel wire armour,extruded flame

retardant PVC sheath.

 

Minimum bending radius:

Type 1 8 x diameter.

Type 2 12xdiameter.

 

Temperature rating

During Operation:-40 ℃+70℃

During Installation:-0 ℃+50℃

     
These cables are not for direct connection to the public mains supply
 
Electrical characteristics

Parameter

Note

Unit

Conductor size

0.5mmsq
(16/0.2mm)

0.75mmsq
(24/0.2mm)

Conductor resistance

Multicore

max.

Ω/Km

39
39.7

26
26.5

Multipair

Insulation resistance

min.

MΩxKm

25

25

Mutual capacitance at 1 kH
Mutual capacitance of the pairs or adjacent cores

max.

pF/m

250

250

Capacitance between any core or screen

max.

pF/m

450

450

Inductance/resistance ratio(L/R)

max.

μH/Ω

25

25

Test voltage

(Core:core)

-

V

V

1000

1000

1000

1000

(Core:core)

Rated voltage

max.

V

300/500

300/500

 
MULTIPAIR INSTRUMENTATION CABLES (UNARMOURED) TO BS 5308 PART 1-COLLECTIVELY SCREENED

Part No.

Conductor

Number of Pairs

Nominal Overall Dia(mm)

Approx Weight (kg/km)

BS5308-PE-MP-CS-1*0.8mm

1/0.8mm
(0.5mm 2 )

1
2(Quad)
5
10
20
30

5.7
6.5
11.0
14.4
18.8
22.4

40
60
130
220
380
540

BS5308-PE-MP-CS-16*0.2mm

16/0.2mm
(0.5mm 2 )

1
2(Quad)
5
10
20
30

6.4
7.3
12.5
16.6
21.7
26.3

60
80
200
340
570
790

BS5308-PE-MP-CS-24*0.2mm

24/0.2mm
(0.75mm 2 )

1
2(Quad)
5
10
20
30

6.7
7.7
13.7
18.1
23.9
28.9

75
100
250
450
800
1130

BS5308-PE-MP-CS-1*1.13mm

1/1.13mm
(1.0mm 2 )

1
2(Quad)
5
10
20
30

6.8
7.8
13.7
17.8
23.8
28.4

85
115
290
500
950
1330

BS5308-PE-MP-CS-7*0.53mm

7/0.53mm
(1.5mm 2 )

1
2(Quad)
5
10
20
30

7.7
9.1
15.8
21.0
27.9
33.7

100
150
360
670
1230
1720


MULTIPAIR INSTRUMENTATION CABLES(UNARMOURED) TO BS 5308 PART 1 TYPE 1-INDIVIDUAL PAIR AND COLLECTIVELY SCREENED

Part No.

Conductor

Number of Pairs

Nominal Overall Dia(mm)

Approx Weight (kg/km)

BS5308-PE-MP-ISCS-1*0.8mm

1/0.8mm
(0.5mm 2 )

2
5
10
20
30

9.7
12.9
17.7
22.9
27.3

100
190
320
570
820

BS5308-PE-MP-ISCS-16*0.2mm

16/0.2mm
(0.5mm 2 )

2
5
10
20
30

11.4
14.6
20.5
26.7
31.7

160
250
480
780
1100

BS5308-PE-MP-ISCS-24*0.2mm

24/0.2mm
(0.75mm 2 )

2
5
10
20
30

12.2
15.7
21.8
28.5
33.7

190
270
550
960
1320

BS5308-PE-MP-ISCS-1*1.13mm

1/1.13mm
(1.0mm 2 )

2
5
10
20
30

12.2
15.6
22.0
29.2
34.8

190
270
480
910
1320

BS5308-PE-MP-ISCS-7*0.53mm

7/0.53mm
(1.5mm 2 )

2
5
10
20
30

13.7
17.8
25.2
33.8
40.0

250
400
800
1400
2040

MULTIPAIR INSTRUMENTATION CABLES (ARMOURED) TO BS 5308 PART 1 TYPE 2-COLLECTIVELY SCREENED

Part No.

Conductor

Number of Pairs

Nominal Dia
under Armour
(mm)

Nominal
Overall Dia
(mm)

Armour Wire
Dia(mm)

Approx Weight (kg/km)

BS5308-PE-MP-ISCS-1*0.8mm

1/0.8mm
(0.5mm 2 )

1
2(Quad)
5
10
20
30

5.3
6.1
10.6
14.0
18.4
22.0

10.1
10.9
15.6
20.1
25.4
29.2

0.9
0.9
0.9
1.25
1.6
1.6

225
250
430
730
1200
1500

BS5308-PE-MP-ISCS-16*0.2mm

16/0.2mm
(0.5mm 2 )

1
2(Quad)
5
10
20
30

4.5
6.9
9.9
16.2
22.3
32.9

10.8
11.7
17.3
22.3
28.5
33.3

0.9
0.9
0.9
1.25
1.6
1.6

250
300
560
970
1640
2110

BS5308-PE-MP-ISCS-24*0.2mm

24/0.2mm
(0.75mm 2 )

1
2(Quad)
5
10
20
30

6.3
7.3
13.3
17.7
23.5
28.5

11.1
12.3
19.2
24.7
30.7
36.9

0.9
0.9
1.25
1.6
1.6
1.6

280
330
750
1260
1890
2440

BS5308-PE-MP-ISCS-1*1.13mm

1/1.13mm
(1.0mm 2 )

1
2(Quad)
5
10
20
30

6.4
7.4
13.2
17.4
23.3
28.0

11.2
12.4
19.1
23.7
30.6
35.6

0.9
0.9
1.25
1.25
1.6
1.6

290
345
790
1310
2040
2640

BS5308-PE-MP-ISCS-7*0.53mm

7/0.53mm
(1.5mm 2 )

1
2(Quad)
5
10
20
30

7.3
13.3
21.1
27.4
27.5
27.8

12.3
13.7
21.5
27.8
35.1
41.9

0.9
0.9
1.25
1.6
1.6
1.6

330
420
940
1050
2400
3120

MULTIPAIR INSTRUMENTATION CABLES (ARMOURED) TO BS 5308 ART1TYPE 2-INDIVIDUAL PAIR AND COLLECTIVELY SCREENED

Part No.

Conductor

Number of Pairs

Nominal Dia
under Armour
(mm)

Nominal
Overall Dia
(mm)

Armour Wire
Dia(mm)

Approx Weight (kg/km)

BS5308-PE-MP-ISCSA-1*0.8mm

1/0.8mm
(0.5mm 2 )

2
5
10
20
30

10.1
13.5
18.3
23.5
27.9

14.3
18.4
23.6
29.7
34.3

0.9
1.25
1.25
1.6
1.6

411
686
1037
1664
2136

BS5308-PE-MP-ISCSA-16*0.2mm

16/0.2mm
(0.5mm 2 )

2
5
10
20
30

12.0
15.2
21.1
27.3
32.3

15.8
20.1
27.0
33.3
39.6

0.9
1.25
1.6
1.6
2.0

460
760
1300
1870
2620

BS5308-PE-MP-ISCSA-24*0.2mm

24/0.2mm
(0.75mm 2 )

2
5
10
20

12.8
16.2
22.6
29.8

16.8
21.1
28.6
37.0

0.9
1.25
1.6
2.0

500
920
1610
2420

BS5308-PE-MP-ISCSA-1*1.13mm

1/1.13mm
(1.0mm 2 )

2
5
10
20

12.8
16.2
22.6
29.8

17.0
21.3
28.8
37.2

0.9
1.25
1.6
2.0

515
950
1670
2540

BS5308-PE-MP-ISCSA-7*0.53mm

7/0.53mm
(1.5mm 2 )

2
5
10
20

14.7
18.4
26.5
28.0

19.5
24.5
32.3
41.3

1.25
1.6
1.6
2.0

730
1180
1820
3030

Colour Code Chart 1
(For Multipair PE insulated Collective Screened Cables to BS 5308 Part1.)
Two-pair unscreened cables are cabled in quad formation and colour coded in clockwise order of rotation,
black,blue,green,brown.
All other cables up to 50 pairs conform to the following coding:

Pair No.

‘A' Wire

‘B' Wire

Pair No.

‘A' Wire

‘B' Wire

1.

Black

Blue

26.

White

Yellow

2.

Black

Green

27.

Red

Yellow

3.

Blue

Green

28.

Orange

Yellow

4.

Black

Brown

29.

Black

Grey

5.

Blue

Brown

30.

Blue

Grey

6.

Green

Brown

31.

Green

Grey

7.

Black

White

32.

Brown

Grey

8.

Blue

White

33.

White

Grey

9.

Green

White

34.

Red

Grey

10.

Brown

White

35.

Orange

Grey

11.

Black

Red

36.

Yellow

Grey

12.

Blue

Red

37.

Black

Violet

13.

Green

Red

38.

Blue

Violet

14.

Brown

Red

39.

Green

Violet

15.

White

Red

40.

Brown

Violet

16.

Black

Orange

41.

White

Violet

17.

Blue

Orange

42.

Red

Violet

18.

Green

Orange

43.

Orange

Violet

19.

Brown

Orange

44.

Yellow

Violet

20.

White

Orange

45.

Grey

Violet

21.

Red

Orange

46.

Black

Turquoise

22.

Black

Yellow

47.

Blue

Turquoise

23.

Blue

Yellow

48.

Green

Turquoise

24.

Green

Yellow

49.

Brown

Turquoise

25.

Brown

Yellow

50.

White

Turquoise


ORDERING OPTIONS:

1) Conductor: Bare or Tinned Conductor
2) Conductor Size: Solid or Stranded(to IEC 228 Class 2 or 5 or 6)

Size

Class1

Class2

Class5

Class6

0.5mm 2
0.75mm 2
1.0mm 2
1.5mm 2
2.5mm 2

1/0.8mm

1/1.13mm

7/0.3mm
7/0.43mm
7/0.44mm
7/0.53mm
7/0.67mm

16/0.2mm
24/0.2mm
32/0.2mm
30/0.25mm
50/0.25mm

28/0.15mm
42/0.15mm
56/0.15mm
84/0.15mm
140/0.15mm

3)Insulation: PE/XLPE/LSF/LSOH
4)Screening: Aluminium Tape/Copper Braiding
5)Cabling: Multicore/Multipair/Multitriple
6)Bedding & Sheathing Material: PE/PVC/LSF/LSOH
7)Armouring: Steel Tape Armouring/Steel Wire Armouring
8)Fire Performance:
IEC 332-1(For Flame Retardant PVC sheath)
IEC 332-3C(For Flame Retardant PVC or LSOH sheath)
IEC 1034 Part 1&2 (For LSOH sheath)
IEC 754 Part 1&2 (5%-15% for LSF sheath & 0.5% for LSOH sheath)
Oxygen Index(32%-40% depending on different LSOH compound )
Temperature Index(250 ℃ to 300 ℃, depending on different LSOH compound)

   
  Copyright © 1995 - 2022 Intercable. All rights reserved.
  E-mail:intercable@intercable.com.hk