CT100 + 4 CORE CABLE |
|
Product Name/Code :
CT100 + 4 CORE CABLE |
Application : For communication and signal control systems. |
Reference Standard :
Customer's sample spec. and the general standard |
Fire Performance :
Flame Propagation Test to IEC 60332 Part 1 ( PVC /LSOH)
Flame Propagation Test to IEC 60332 Part 1 and Part 3 ( FRPVC/LSFROH )
Determination of the amount Halogen Acid Gas to IEC 60754 Part 1 ( LSOH )
Smoke Density Test to IEC 61034 ( LSOH )
Oxygen Index Test to BS 2863 or ISO 4589-2 ( LSOH )
Temperature Index Test to BS 2782 or ISO 4589-3
( LSOH ) |
|
|
Cable Construction |
Electrical Performance |
Center Conductor |
A |
B |
Max. Conductor DC Resistance at 20 ℃ ( Ω /Km ) 8 9.00 |
|
Single |
Bare Copper |
Bare Copper |
A |
<23.7 |
Construction |
1.00/1 |
16/0.20 |
B |
<37.04 |
Diameter (mm) |
1.00 |
0.92 |
Min. Insulation DC Resistance at 20 ℃ ( M Ω *Km ) |
>200 |
Insulation
Min. Thickness(mm) |
Cellular PE
3.60 |
PVC
0.44 |
Voltage Rating(V) |
30 |
Operating Temperature( ℃ ) |
80 |
Insulation Diameter (±0.03mm) |
4.60 |
1.80 |
Capacitance(pF/m) |
<58 |
CU/Polyester tape |
115% |
|
Velocity ratio (+/-5%) |
80 |
Braid Shield |
Bare Copper Shield |
Impedance( Ω ) |
75+/-3 |
Construction |
16/4/0.14 |
Attenuation at 20 ℃ (-dB/100m) |
|
Braid coverage(%) |
>56% |
50MHz |
4.6 |
Inner Sheathing |
PVC |
100MHz |
6.9 |
Min. Thickness(mm) |
1.03 |
200MHz |
8.4 |
Diameter(±0.10mm) |
6.50 |
400MHz |
12.2 |
Mylar twist(over lapping,%) |
>=25% |
700MHz |
17.9 |
Outer Sheathing |
PVC |
900MHz |
18.8 |
Min. Thickness(mm) |
0.8 -- 1.15 |
1000MHz |
22.5 |
Diameter(±0.10mm) |
10.60 |
|
|
Sheathing Compound |
PVC/LSF/LSOH |
|
|
Core Identification/Color Code |
According to customer request |
|
|
Bending Radius |
6xOverall Diameter |
|
|
Temperature Rating |
70C |
|
|
Voltage Rating |
|
|
|
|
300/500V |
|
|
|
|
|
|
|
|
|
|
|
|