Product Name/Code :
RG223
Application :
For communication and signal control systems.
Reference Standard : Customer's sample spec. and the general standard
Fire Performance :
Flame Propagation Test to IEC 60332 Part 1 ( PVC /LSOH)
Flame Propagation Test to IEC 60332 Part 1 and Part 3 ( FRPVC/LSFROH )
Determination of the amount Halogen Acid Gas to IEC 60754 Part 1 ( LSOH )
Smoke Density Test to IEC 61034 ( LSOH )
Oxygen Index Test to BS 2863 or ISO 4589-2 ( LSOH )
Temperature Index Test to BS 2782 or ISO 4589-3 ( LSOH )
Cable Construction |
Electrical Performance |
Center Conductor |
Silver Plated Copper |
Electrical Characteristics: |
|
Dia. |
1/0.91 |
Frequency |
Attenuation |
Insulation |
Solid PE |
(MHz) |
(dB/100m) |
Nom. Thickness(mm)
Insulation Dia. (±0.03mm) |
1.0
2.95 |
50 |
6.1 |
100 |
12.0 |
Bonded Al Foil +Silver Plated Copper Braid Shield 1 |
|
200 |
21.6 |
Construction |
16/ 6/0.12 |
400 |
30.5 |
Coverage Area(%) |
>=75 |
700 |
33.7 |
Bonded Al Foil +Silver Plated Copper Braid Shield 2 |
|
900 |
44.5 |
Construction |
6/ 7/0.12 |
1000 |
46.8 |
Coverage Area(%) |
>=90 |
Operating Temperature( ? ) |
80 |
Jacket |
PVC |
Capacitance(pF/m) |
100 |
Nom. Thickness(mm) |
1.05 |
Velocity ratio (+/-5%) |
66.6 |
Cable Dia.(±0.10mm) |
5.3 |
Impedance(+/-3 Ω ) |
50 |
Jacket Compound |
PVC/LSF/LSOH |
|
|
Core Identification/Color Code |
According to customer request |
Bending Radius |
6 x Overall Diameter |
Temperature Rating |
70 ℃ |
Voltage Rating |
300/500V |
|
|
|