Application :
Signaling and control in trailing chains, Dynamic applications.
Service Voltage
250V 300V 300/500V 450/750V 600/1000V
Test Voltage
1500V/2000V/3000V/4000V
Construction
Conductors : |
extra-flexible class 6 acc. Standards VDE 0295 - IEC 228 - CEI 20-29 tinned copper |
Insulation : |
Special PVC compound according IEC-VDE-CEI PETP polyester terephtalate
|
EMC shielded : |
tinned copper braid on total -covering >/= 85% |
Taping : |
Special tape |
Jacket : |
special PVC compound/ polyurethane PUR abrasion-free |
Min. Bending Radius |
10 x external cable diam |
APPLICATION :
Supply of Indramat brushless motors. Trailing chains. Dynamic applications. Robotics.
TECHNICAL CHARACTERISTICS
Service Voltage :
450/750V power conductors 250V signal conductors
Test Voltage :
3000V power conductors 1000V signal conductors
Insulation Resistance :
>/= 100 Mohm x km (at 20oC)
Temperature :
service from -10oC to + 80oC storage from -30oC to + 80oC
Conductor Stranding :
extra-flexible class 6 acc. Standards VDE 0295 - IEC 228 - CEI 20-29
Primary Insulation :
power: Special PVC compound signal: PETP polyester terephtalate
Conductors Identification :
power: black numbered 1-2-3 + YE/GRN signal: black numbred 5-6-7-8
EMC shield (for type 12) :
on total: tinned copper braid covering >/= 85% signal: alum/pol + tinned copper braid
Taping :
special tape
Jacket :
special PUR compound abrasion-free colour orange RAL 2003
Min. Bending Radius:
10 x external cable diameter
Translation Speed :
180 m/min.
Max. Acceleration :
7 m/s2
Type 11- unshielded |
Part No. |
Cond. Nr. x section
Nr. x mm 2 |
Ext. Diam.
mm |
CU-weight
kg/km |
ATL-RC-11U-4x0.75 |
(4x0.75)+2x(2x0.34) |
11.2 |
42 |
ATL-RC-11U-4x1.00 |
(4x1)+2x(2x0.75) |
12.2 |
68 |
ATL-RC-11U-4x1.50 |
(4x1.5)+2x(2x0.75) |
13.4 |
87 |
ATL-RC-11U-4x2.50 |
(4x2.5)+2x(2x0.75) |
15.2 |
125 |
ATL-RC-11U-4x4.00 |
(4x4)+2x(2x1) |
17.4 |
192 |
ATL-RC-11U-4x6.00 |
(4x6)+2x(2x1) |
20.6 |
170 |
ATL-RC-11U-4x10.0 |
(4x10)+2x(2x1) |
22.2 |
423 |
ATL-RC-11U-4x16.0 |
(4x16)+2x(2x1) |
25.4 |
653 |
ATL-RC-11U-4x25.0 |
(4x25)+2x(2x1.5) |
29.3 |
1017 |
ATL-RC-11U-4x35.0 |
(4x35)+2x(2x1.5) |
33.4 |
1402 |
|
|
Type 12- unshielded |
Part No. |
Cond. Nr. x section
Nr. x mm 2 |
Ext. Diam.
mm |
CU-weight
kg/km |
ATL-RC-11U-4x0.75 |
(4x0.75)+2x(2x0.34) |
12.1 |
103 |
ATL-RC-11U-4x1.00 |
(4x1)+2x(2x0.75) |
12.9 |
137 |
ATL-RC-11U-4x1.50 |
(4x1.5)+2x(2x0.75) |
14.1 |
160 |
ATL-RC-11U-4x2.50 |
(4x2.5)+2x(2x0.75) |
15.9 |
200 |
ATL-RC-11U-4x4.00 |
(4x4)+2x(2x1) |
18.6 |
321 |
ATL-RC-11U-4x6.00 |
(4x6)+2x(2x1) |
20.8 |
407 |
ATL-RC-11U-4x16.0 |
(4x10)+2x(2x1) |
23.4 |
576 |
ATL-RC-11U-4x25.0 |
(4x16)+2x(2x1) |
26.6 |
825 |
ATL-RC-11U-4x25.0 |
(4x25)+2x(2x1.5) |
30.2 |
1220 |
ATL-RC-11U-4x35.0 |
(4x35)+2x(2x1.5) |
34.2 |
1630 |
|
Reference Standards :
VDE 0472-804 B - IEC 332.1 - CEI 20 - 35 for flame resistance VDE 0472-803-B for ASTM2 oil resistance CNOMO E.03.40.150 N - NFT 46.013 for resistance to industrial oils VDE 0472-815 halogen-free version
|