Application
Signaling and control in trailing chains, Dynamic applications.
Service Voltage
250V 300V 350V 300/500V 450/750V 1000V
Test Voltage
1500V 2000V 3000V
Construction
Conductors : |
extra-flexible class 6 acc. Standards VDE 0295 - IEC 228 - CEI 20-29 tinned copper |
Insulation : |
Special PVC compound according IEC-VDE-CEI
PETP polyester terephtalate
XLPE cross-linked polyethylene |
EMC shielded : |
tinned copper braid on total -covering >/= 85%
alum/pol + tinned copper braid
tinned copper spiral coverage.100% |
Taping : |
Special tape |
Jacket : |
special PVC compound/ polyurethane PUR abrasion-free
TPPE thermoplastic polyester polyether elastomer |
Code |
Formation |
Ext.Diam mm |
CU-weight kg/km |
R7B9RDX |
3x(2x0.14) + 1x(3x0.14) |
7.1 |
27 |
APPLICATION :
Special cable "resolver" for robots, Dynamic applications.
TECHNICAL CHARACTERISTICS :
Service Voltage :
250V
Test Voltage :
1500V
Insulation Resistance :
>/= 3000 Mohm x km (at 20oC)
Capacitance :
abt. 85 nF/km at 20oC
Temperature :
service from 0oC to +80oC, storage from -40oC to + 80oC
Conductor Stranding :
extra-flexible class 6 acc. Standards VDE 0295 - IEC 228 - CEI 20-29 tinned copper
Primary Insulation :
XLPE cross-linked polyethylene
Conductors Identification :
3 pairs: (NAT-RD) - (NAT-BL) - (NAT-BLK) 1 tern: BR - BLK - BLUE
Shield :
3 pairs 2 x 0.14: tinned copper spiral cov. abt. 95%
Taping :
special tape
Jacket :
TPPE thermoplastic polyester polyether elastomer black colour RAL 9005
Min. Bending Radius :
100mm
Translation Speed :
180m/min.
Max. Acceleration :
5m/s2
Reference Standards :
VDE 0472-804 B - IEC 332.1 - CEI 20-35 for flame resistance VDE 0472-815 halogen-free version.
|