Application:
This cable is used for interconnecting between frames of PCM equipments
with 120W characteristic impedance.
Conductor:
Annealed bare copper or tinned copper
Insulation:
Foamed PE / HDPE
Shielded:
Two wires are twisted to form a pair then shielded with a layer of Al-Mylar
foil. A piece of tinned copper wire is added along with the pair as drain wire.
Assembly:
Suitable number of pairs are assembled to form a cable core.
Overall shield:
a. Layer of Al-Mylar foil with a drain wire.
Sheath:
PVC (polyvinyl Chloride)or LSNHFRPE.( ow-moke Non-Halogen Flame Retardant Polyethylene).
Structur
Conducyor |
Pair |
Insulation |
Cable core |
Sheath |
Overall |
Standard |
Diameter(mm) |
(P) |
Diameter(mm) |
Diameter(mm) |
Thickness(mm) |
Diameter(mm) |
Length(M) |
0.5 |
1 |
1.3 |
3.5 |
0.6 |
5.0 |
200 |
2 |
6.0 |
0.6 |
7.5 |
200 |
4 |
7.0 |
0.6 |
8.5 |
500 |
8 |
10.0 |
0.6 |
11.5 |
500 |
10 |
10.0 |
0.6 |
11.5 |
500 |
16 |
13.5 |
0.8 |
16.0 |
500 |
22 |
16.0 |
1.0 |
18.3 |
500 |
25 |
16.0 |
1.0 |
18.5 |
500 |
32 |
19.0 |
1.0 |
21.5 |
500 |
40 |
21.0 |
1.5 |
24.5 |
500 |
Characteristics:
Items |
Specification |
Conductor Resistance (20℃) |
Max.100.2W / Km |
Conductor Resistance unbalance(20℃) |
Max.5 ﹪ |
Insulation Resistance (20℃,DC 500V / 1min.) |
Min.5000M - Km |
Dielectric strength |
DC 1000V / 1min. Between Conductors |
DC 1500V / 1min. Between Conductors and shield |
Static Capacitance (1KHz) |
Max.50 nf / Km |
Attenuation. (1024 KHz) |
Max.34 dB / Km |
Characteristic Impedance (1024 KHz) |
120 ± 10W |
Near-end cross talk (1024 KHz) |
Min.70 dB / 500M |
|