Conductor:
Annealed Copper Wire (Bare Single,Bare Strand or Tinned Strand) or Copper-Plated Steel Wire.
Insulation:
PE(Polyethylene)or XLPE (Cross-Linked Polyethylene)
Braid shield:
Annealed Copper Wire (Tinned Copper)
Sheath:
PVC( Polyvinyl Chloride)
Structure:
Conductor |
CPE Insulation |
Braid Shield |
Sheath |
AWG |
Construction |
Diameter |
Min. Thickness |
Nominal
Thickness |
Diameter |
Construction |
Diameter |
Min.
Thickness |
Nominal
Thickness |
Diameter |
30 |
7 / 0.10A |
approx.0.30 mm |
0.508 mm |
0.675 mm |
1.65 ± 0.10 mm |
16/5/0.10 |
approx.2.15mm |
0.305mm |
0.475mm |
3.10 ± 0.20 mm |
|
30 |
1 / 0.26ACP |
approx.0.26 mm |
0.695 mm |
1.65 ± 0.10 mm |
16/5/0.10 |
approx.2.15mm |
0.305mm |
0.475mm |
3.10 ± 0.20 mm |
|
28 |
1 / 0.32 ACP |
approx.0.32 mm |
0.84 mm |
2.00 ± 0.10 mm |
16/5/0.10 |
approx.2.50mm |
0.305mm |
0.75mm |
4.00 ± 0.20 mm |
|
28 |
1 / 0.32A |
approx.0.32 mm |
0.695 mm |
2.00 ± 0.10 mm |
16/5/0.10 |
approx.2.50mm |
0.305mm |
0.75mm |
4.00 ± 0.20 mm |
|
26 |
7 / 0.16A |
approx.0.48 mm |
0.685 mm |
1.85 ± 0.10 mm |
16/5/0.10 |
approx.2.35mm |
0.305mm |
0.575mm |
3.50 ± 0.20 mm |
|
24 |
7 / 0.20A |
approx.0.60 mm |
0.725 mm |
2.05 ± 0.10 mm |
16/5/0.10 |
approx.2.55mm |
0.305mm |
0.525mm |
3.60 ± 0.20 mm |
|
24 |
11 / 0.16TA |
approx.0.61 mm |
0.72 mm |
2.05 ± 0.10 mm |
16/5/0.10 |
approx.2.55mm |
0.305mm |
0.525mm |
3.60 ± 0.20 mm |
Characteristics:
Items |
Specification |
Rating |
UL:60℃ 300V |
Dielectric Strength |
AC 500V / min.(Between Conductor and Shield) |
Spark Test AC 2000V / 0.15sec. |
Insulation |
Min.1000MW - Km (20℃) at DC 500V for PE |
Min.50MW - Km (20℃) at DC 500V for FRPE |
Flame Tesst |
UL:VW - 1 |
|