Shield Cable
|
|
|
|
Conductor:
Tinned Copper Strand
Insulation:
FRPE (Flame Retardant Polyethylene)
Wrapping Shield:
Bare or Tinned Copper Wires Wrapped Insulation.
Sheath:
PVC( Polyvinyl Chloride)
Structure:
Conductor |
Insulation |
Wrapping Shield |
Sheath |
AWG |
Construction |
Diameter |
Min.
Thickness |
Nominal
Thickness |
Diameter |
Construction |
Diameter |
Min.
Thickness |
Nominal
Thickness |
Diameter |
32 |
7 / 0.08TA |
approx.
0.24 mm |
0.178 mm |
0.23
mm |
0.70 ± 0.10 mm |
27 / 0.08 |
approx.
0.86 mm |
0.178mm |
0.22mm |
1.30 ± 0.10 mm |
30 |
7 / 0.10TA |
approx.
0.30 mm |
0.178 mm |
0.225 mm |
0.75 ± 0.10 mm |
24 / 0.10 |
approx.
0.95 mm |
0.178mm |
0.225mm |
1.40 ± 0.10 mm |
28 |
7 / 0.13TA |
approx.
0.39 mm |
0.178 mm |
0.23
mm |
0.85 ± 0.10 mm |
27 / 0.10 |
approx.
1.05 mm |
0.178mm |
0.225mm |
1.50 ± 0.10 mm |
26 |
7 / 0.16TA |
approx.
0.48 mm |
0.178 mm |
0.235 mm |
0.95 ± 0.10 mm |
29 / 0.10 |
approx.
1.15 mm |
0.178mm |
0.25mm |
1.65 ± 0.10 mm |
24 |
7 / 0.20TA |
approx.
0.60 mm |
0.178 mm |
0.225 mm |
1.05 ± 0.10 mm |
32 / 0.10 |
approx.
1.25 mm |
0.178mm |
0.25mm |
1.75 ± 0.10 mm |
Characteristics:
Items |
Specification |
Rating |
UL:80℃ 30V |
Dielectric Strength |
Spark Test AC 1000V / 0.15sec. |
Insulation Resistance |
Min.5MW - Km (20℃) at DC 500V |
Flame Test |
UL:VW – 1SC |
|
|
|