Germany Standard
Single-core cable
FL4G11Y
Application
Automotive EVAinsulated ,PURsheathed multi-cores cable is used for ABS braking systems, wiring inside the engine compartment.
Construction:
Conductor:
cu-ETP1 tinned according to DIN EN 13602
Insulation:
Ethylene vinyl acetate (EVA)
Sheath:
Polyurethane(PUR)
Standard Compliance:
ISO 6722
Technical Parameters:
Operating temperature:–40 °C to +125 °C
|
Conductor |
Insulation |
Cable |
Nominal
Cross
-section |
No.
and
Dia.of
Wires |
Diameter
max. |
ElectricalResistanceat
20°Cmax. |
Thickness Wallnom. |
Diameter
of Core |
Sheath
Thickness |
Overall Diameter
min. |
Overall Diameter
max. |
Weight
approx. |
mm2 |
No./mm |
mm |
mΩ/m |
mm |
mm |
mm |
mm |
mm |
kg/km |
2x 0.50 |
16/0.21 |
1.00 |
40.10 |
0.60 |
2.20 |
0.85 |
5.90 |
6.30 |
44 |
2x0.75 |
40/0.16 |
1.10 |
27.10 |
0.50 |
2.20 |
0.90 |
5.90 |
6.45 |
49 |
2x1.50 |
30/0.26 |
1.70 |
13.70 |
0.60 |
2.80 |
0.65 |
6.60 |
7.00 |
66 |
3x0.50 |
16/0.21 |
1.00 |
40.10 |
0.60 |
2.20 |
0.80 |
6.00 |
6.40 |
51 |
3x1.50 |
30/0.26 |
1.70 |
13.70 |
0.70 |
2.90 |
1.10 |
8.10 |
8.70 |
107 |